摘要: 频谱仪一般50欧电缆,让线缆形成一个闭合的回路,并要留有磁通量通过的面积即可,从而形成一个简易的等效探头。 频谱仪LOOP探头 一般是找一根比较好的射频线缆拨开,将里面的芯绕成圆环状接在外围的地线上即可。 ...
频谱仪一般50欧电缆,让线缆形成一个闭合的回路,并要留有磁通量通过的面积即可,从而形成一个简易的等效探头。 频谱仪LOOP探头 一般是找一根比较好的射频线缆拨开,将里面的芯绕成圆环状接在外围的地线上即可。 E- and H-Field Probes - The close field probes are constructed from semi-rigid coax (see photo above). The simplest design for an h-field probe merely takes the center conductor, bends it around and solders it to the shield in a loop. The larger the loop diameter, the more sensitivity, but less resolution. Because these probes are geometrically unbalanced, a small ferrite choke clamped around the coax near the connector will help keep common-mode currents from flowing along the outside of the shield and disrupting your measurements. The e-field probe is constructed by stripping away a small part of the outer shield. It’s wise to cover the probes with an insulating material, such as “tool dip” (red coating above) to avoid shorting the product under test. Currently, for a “quick and dirty” probe, you may also use a length of standard coax cable. Strip out the center conductor, bend it around in a loop and solder it the the braided shield (as in the “micro” loop pictured above). 频谱仪Probe探针 可以用一个高压隔离电容,串联在50ohm同轴电缆的芯线上,即电容一头接同轴线缆靠近频谱这端、另外一头用一块PCB固定,然后用一根比较硬的钢针连接,然后就可以用了。 |
我们坚持大道至简,实干为要,为您提供坚强有力的技术支撑。我们相信为您提供有意义的选项,符合您个人偏好的方式更改您的产品,让您的产品更具价值。
全部采用ETS-Lindgren、Rohde&Schwarz、Keysight、Schwarzbeck、California Instruments、EMTEST、Tektronix等进口设备,为精准测试提供了保障。
为您提供综合EMC方案与材料一站式解决方案,成熟可靠、稳定的物料供应,不用担心设计研发时的物料与生产过程的差异,导致与认证标准的差异,带来市场准入风险。
我们将致力于电磁兼容,探索周边扩展为您提供更多价值,让合作更具活力与务实高效,提高市场竞争力。
频谱仪探头具体制作方法:
1、探针,主要是针对芯片的具体pin、具体到某个io、信号、vcc等网络,进行具体的精准定位。
探针的制作要点,因为是要将探头直接连接到具体的产品,例如接到pcb上去,特别是一些vcc电源会有电压,这样如果直接连到频谱仪,这样就会烧掉昂贵的频谱分析仪。所以,一定要加隔离,且是要高压隔离电容,至少满足电压2kv以上。最好用无感电容、容量可以针对不同频率、酌情选择。为了安全起见,一般选取1000pf左右,或更小。
频谱分析仪接口
2、环形探头
环形探头制作要点是靠感应电磁场形成回路,绕的圈数越多,感应的信号越强。当然,这样就会让探头变大,就无法精准感应到某个区域。